Específicaciones Generales:
Measurement function: DC Voltage, AC Voltage, DC Current, AC Current, Resistance, Frequency, Temperature, Capacitor, Continuity Check, Diode Test Effective value (root mean square value) detection (RMS) and mean value detection (MEAN) can be switched during AC voltage measurement (KEW1052 only). The low-pass filter can be switched on/off during AC voltage or AC current measurement.
Other functions: Data Hold (D•H), Auto Hold (A•H), Range Hold (R•H), Maximum value* (MAX), Minimum value* (MIN), Average value* (AVG), Zero Adjustment (Capacitor, Resistance), Relative values, Save to Memory*, Auto Power Off (Approx. 20 minutes), LCD backlight.
* = For model KEW1052 only
Display: 4-digit (LCD)……..7-segment ; Main-display…....6000 counts ; Sub-display…......6000 counts ; Bar graph indicator…..31-segment ; polarity Indicator:…..“–” Appears automatically when the polarity is negative ; Overrange Indicator….. “ OL ” ; Low-battery Indicator….“ +- ” Appears when the batteries become low.
Measurement cycle: 5 times per second (except frequency measurement : one time per second, Resistance measurement (6MΩ/60MΩ) : 2.5 times per second, capacitor measurement (1000μF) : max.0.14 time per second) Bar graph display approx 25 times per second (at AC, Ω)
Operating temperature and humidity ranges: -10 to 55℃, 80%RH or less (no condensation) 70%RH or less at 40 to 55℃.
Storage temperature and humidity ranges: -30 to 70℃, 70%RH or less (no condensation)
Temperature coefficient: (Accuracy at 23±5℃× 0.1)/℃ should be added. (Temperature ranges: -10 to 18℃ and 28 to 55℃)
Power supply: AA-size (R6/LR6) 1.5V batteries: 4
Battery life: Approximately 300 hours (Operating hours of alkaline batteries when in DC voltage-mode.)
Note: The battery life varies depending on the operating conditions.
Withstand voltage: 6.88kVrms AC for five seconds (across input terminals and casing)
Dimensions: Approx. 192(L)×90(W)×49(D)mm
Weight: Approx. 560g (including batteries)
Applicable standards: IEC61010-1 CAT.IV 600V, CAT.III 1000V Pollution degree 2, IEC61010-031, IEC61326-1
Accessories included: Batteries : 4, Test leads: 1set (7220), Fuse (included): 440mA/1000V (8926), 10A/1000V (8927), Instruction manual: 1, Calibration Certificate